skip to content

Vega C/Box Protect 15kW (380V) Gen2 » Buy online now for only R 7,958.00 incl. VAT

R 7,958.00 incl. VATAdd to Basket

Average Delivery Time:

Vega C/Box Protect 15kW (380V) Gen2 image 1

Description

The H931 digital starter is suitable for controlling 380v pump motors between 0.75kw and 15kw and features an IP22 enclosure. The H931 digital starter will protect the motor in the following scenarios: Dry run, overload, transient surge, under and over voltage, pump stall, and short circuit. The H931 starter also features terminals for connecting the H931 starter to remote control devices through the RS485 protocol.

Application

  • Dry run protection
  • Over load protection
  • Transient surge protection
  • Under voltage protection
  • Over voltage protection
  • Open phase protection
  • Pump stalled protection
  • Short circuit protection

Specification

  • 1.75-4kW (1HP-5.5HP)
  • Rated output power: 5.5-11kW (7.5HP-15HP), 15kW (20HP)
  • Trip response time of over load: 5sec-5min
  • Trip response time of open phase: < 2 sec
  • Trip response time of short circuit: < 0.1sec
  • Trip response time of under / over voltage: < 5sec
  • Trip response time of dry run: 6sec
  • Recovery time of over load: 30min
  • Recovery time of under / over voltage: 5min
  • Recovery time of dry run: 30min
  • Trip voltage of over voltage: 420V
  • Trip voltage of under voltage: 340V
  • Liquid level transfer distance: ≤1000m

Construction characteristics

  • Working temperature: -25℃ to +55℃
  • Working humidity: 20% - 90%RH, no drips concreted
  • Degree of protection: IP22
  • Install position: Vertical
  • Unit dimensions: ( L x W x H) 37 x 12.5 x 27.6 cm
  • Unit weight (net): 3.6kg

This product can be found under